91
Environment Sensor: Indicates whether the environment sensor has been installed on the UPS/PDU/ATS. Note:
When the sensor cannot be detected anymore, it will be annotated No Response. Users can click the Uninstall to
reflect it if it had been removed physically from the UPS/PDU/ATS.
Status
The Status tab displays details about the UPS/PDU/ATS.
Current: The output current in Amps.
Outlets: The status of each outlet on the UPS/PDU/ATS and the name of the connected computer or equipment.
Input: Displays the status of the utility power supplied to the UPS.
Voltage: The voltage of the utility power supplied to the UPS.
Frequency: The frequency of the utility power supplied to the UPS in Hertz.
Output: Displays the status of the output power that is being supplied to connected equipment.
Load Consumption: The power draw of the connected equipment expressed as a percentage of the total load
capacity. This displays as watts on some UPS models.
Battery: Displays the status of the battery packs.
Capacity: The capacity of the batteries, expressed as a percentage of full charge.
Remaining Runtime: The estimated amount of time that the UPS can supply power to its load.
System: Displays the operating status of the UPS.
Environment Temperature: Indicates the measured temperature from the environment sensor.
Environment Humidity: Indicates the measured humidity from the environment sensor.
Contact: Indicates generic equipment connects to this sensor. Users can define the name and state in RMCARD
web for each contact and monitor the state is normal.
Source A Voltage: The voltage of the input power supplied to the source A of ATS.
Source B Voltage: The voltage of the input power supplied to the source B of ATS.
Load: The power draw of PDU/ATS supplying power to connected equipments.
Bank # Load: The power of the PDU/ATS bank supplied power to the connected equipments.
Information
Information tab shows information about the UPS/PDU/ATS.
Type: The type of the device, such as On-Line, Line Interactive or Sinewave Line Interactive for UPS; or
Monitored or Switched for PDU/ATS.
Model Name: The model name of the UPS/PDU/ATS.
Firmware Version: The firmware version of the UPS/PDU/ATS.
MAC address: The MAC address of the UPS RMCARD, PDU or Agent computer's network interface.
Serial Number: The serial number of the UPS.
Note: This will give the internal serial number on some models.
Power Rating: The Volt-Amp rating (VA) and power rating (Watts) of the UPS.
Voltage Rating: The output voltage rating (Volts) of the UPS.
Frequency Rating: The output frequency rating (Hz) of the UPS.